Sale!

ABB 1MRK000284-ABR02 Power Supply Module | ABB Relion Protection & Control

Original price was: $999.00.Current price is: $888.00.

Brand: ABB

Model: 1MRK000284-ABR02

Type: Power Supply Module

Series: Relion Series

Core Function: System Power Supply & Power Distribution

Country Of Origin: Sweden

Condition: New Original

Availability: Ready Stock

Warranty: 12 Months

Category: SKU: 1MRK000284-ABR02 Brand:
  • Need Help?
  • +86 13313703791
  • +86 13313703791
  • seren@ymgkplc.com
库存图标
100,000+ Models in Stock
保修图标
One-Year Warranty
响应图标
24h Fast Response

Description

PRODUCT OVERVIEW

ABB 1MRK000284-ABR02 is a plug-in binary input board specially matched with ABB Relion 650 & 670 series protection control devices. It is responsible for collecting position signals of circuit breakers, isolating switches, auxiliary relays and other field switching quantities in the substation primary system, converting external passive/active switching signals into standard digital signals identifiable by the IED main control board, and uploading status data for bay logic judgment, equipment state monitoring and fault event recording.

Every channel adopts optocoupler isolation design with built-in surge absorption and filtering circuits, which can effectively resist instantaneous overvoltage and strong electromagnetic interference in substation sites. Widely applied in routine maintenance, fault replacement and emergency spare backup of feeder protection, transformer protection, busbar protection and generator protection equipment in power transmission & distribution systems.

TECHNICAL SPECIFICATIONS

Item Parameter Details
Part Number 1MRK000284-ABR02
Product Type BIM binary input signal acquisition board
Channel Configuration Multi-channel isolated binary input
Rated Input Voltage Universal 24VDC ~ 250VDC adaptive input
Isolation Mode Single-channel independent optical isolation, withstand voltage ≥2000VAC
Signal Indication Corresponding LED status indicator for each input channel
Working Temperature -25℃ ~ +70℃ continuous stable operation under full load
Storage & Transport Temperature -40℃ ~ +85℃
Internal Bus Internal backplane bus communication with relay CPU board
Additional Function Configurable input filtering delay, channel self-diagnosis detection
Installation Method Standard golden finger backplane pluggable card structure
Execution Standards IEC60255 relay standard, IEC61000 EMC anti-interference, CE certification
Origin Sweden
Product Attribute Original genuine binary input spare part for Relion series protection equipment

COMMERCIAL PROCUREMENT MANAGEMENT

  1. System Compatibility Audit: Professional power hardware engineers verify your protection equipment model, rack slot version and firmware version to realize zero-modification seamless replacement.
  2. Graded volume discount mechanism: Optimized unit price matching different purchase quantities; real-time inventory data and international logistics expense information are updated synchronously.
  3. Full-set export document service: Provide standardized complete export materials and unified HS code declaration scheme to improve customs clearance efficiency for global power industry customers.
  4. Issuance of stamped official commercial PI: Cooperate with the internal financial approval and capital payment workflow of power enterprises through formal stamped proforma invoice.
  5. Standard cross-border settlement mode: Support mainstream international payment methods represented by T/T telegraphic transfer.
  6. Comprehensive pre-delivery performance verification: Each binary input board passes temperature cycle aging test, full-channel signal response calibration, bus communication handshake test and self-diagnosis function trigger test before leaving the warehouse.
  7. Standard anti-damage export packaging scheme: Vacuum ESD sealed bag + customized high-density shockproof foam + pressure-resistant thickened export carton, effectively preventing precision optocoupler devices and PCB solder joints from collision damage during cross-border long-distance transportation.
  8. Authorized Global Logistics Distribution: Cooperate with official operation channels of DHL, FedEx and UPS, and feed back real-time tracking number immediately after goods are delivered to logistics providers.

VISUAL PRODUCT SHOWCASE

  1. Product Photo 1: Overall structural drawing of 1MRK000284-ABR02 board, marking optical isolation components, indicator lamps and golden finger connector area

ABB 1MRK000614-ABR02 CONTROL BOARD 1MRK000007-6

  1. Product Photo 2: Internal layout drawing of signal conditioning circuit and anti-interference protection components

 

MATCHING SUPPORTING SPARES & TECHNICAL DOCUMENTS

Main control CPU board, switching output module, analog sampling board, device power supply card, relay frame backplane assembly, ABB official test report, complete installation dimension drawing and standardized safe replacement operation specification for binary input board,1MRK002239-BBr01 , 1MRK000614-ABr01 ,1MRK002133-ABr03 

AFTER-SALES SERVICE & WARRANTY CLAUSES

12-month quality warranty covers inherent hardware faults generated under rated normal operating conditions, with free testing and replacement service within the warranty scope. All supplied ABB 1MRK000284-ABR02 boards are original genuine products (brand new original packaged spare parts or dismantled used boards after full professional bench calibration). Its signal collection performance parameters and physical installation dimensions are completely consistent with the original factory design standards. We provide electronic delivery of official datasheets, detailed disassembly & replacement specifications and field construction safety guidelines. Long-term free remote technical services cover on-site module replacement guidance, whole protection device signal joint debugging and diagnosis & elimination of switching signal collection faults.

FAQ

What core function does 1MRK000284-ABR02 undertake in protection relays?

It is the switching state perception unit of the protection device, feeding back the actual on-off state of primary switchgear to the main control unit. The protection logic realizes interlock control, fault alarm and trip locking according to breaker position signals, preventing misoperation of protection functions caused by abnormal switch state collection.

Will replacing this binary input board erase the original relay protection fixed values?

Protection setting parameters and logic configuration are stored in the Flash memory of the main control board; replacing the BIM board will not modify any device configuration data, only power-on self-check is required after installation.

Are second-hand dismantled boards fully inspected before delivery?

All recycled used boards go through deep circuit cleaning, optocoupler performance screening, full-channel signal response test and long-time power aging test on professional test benches strictly to restore factory standard performance before shipment.

Delivery cycle for spot goods?

Goods are stored in domestic warehouse, all d

Contact info