Description
📋 Product Core Brief
- Correct Model: ABB REF615 (Relion® 615 Series)
- Ordering Code: 3BDH001000R0001
- Function: Multifunction feeder protection, control, measurement & monitoring relay for MV/LV networks
- Critical Clarification: No ABB product exists as “PM902F”. This ordering code is exclusively assigned to REF615 hardware variant (specific configuration: 3-phase CT inputs, auxiliary power 88–265 V AC/DC, standard I/O).
- Typical Applications: Substation feeders, motor protection, transformer protection, industrial power distribution
⚙️ Key Technical Specifications (3BDH001000R0001 Configuration)
| Parameter | Specification |
|---|---|
| Protection Functions | 50/51 (Phase OC), 50N/51N (Ground OC), 67 (Directional OC), 50BF (Breaker Failure), 79 (Reclosing) |
| Measurement | I, V, P, Q, S, PF, kWh, kVArh (Class 0.5S) |
| Inputs | 3× Phase CT (1/5 A), 1× Residual CT, 4× Binary Inputs |
| Outputs | 3× Binary Outputs (Form C), 1× LED Indicator |
| Communication | 1× Ethernet (IEC 61850, Modbus TCP), 1× RS-485 (Modbus RTU) |
| Auxiliary Power | 88–265 V AC/DC (universal) |
| Standards | IEC 60255, IEC 61850 Ed.2, UL 508, IEEE C37.90 |
| Operating Temp | -25°C to +70°C |
| Mounting | Flush or surface mount (96×96 mm panel cutout) |
| Firmware Tool | PCM600 (Protection and Control IED Manager) |
| Note: Always verify physical label on device. Configuration varies by ordering code suffix. |
ℹ️ Product Introduction
The ABB REF615 (3BDH001000R0001) is a cornerstone of modern power system protection. Engineered for reliability in harsh electrical environments, it delivers sub-cycle fault detection (<20 ms), integrated metering, and seamless SCADA integration via IEC 61850. Its compact 96×96 mm form factor replaces legacy electromechanical relays while providing cyber-secure communication (IEC 62351 support).This specific ordering code denotes a standard feeder protection variant with universal power supply and essential I/O—ideal for cost-sensitive MV feeder applications where advanced arc-flash or synchrocheck functions (found in REF620) are unnecessary.
🔧 Installation & Configuration Essentials
⚠️ SAFETY FIRST: Work must be performed by qualified electrical personnel. De-energize circuit. Follow NFPA 70E / local arc-flash protocols.
Critical Steps:
- Pre-Installation Verification
- Confirm ordering code 3BDH001000R0001 on device label
- Validate CT ratios match project settings (critical for protection accuracy)
- Inspect for shipping damage; verify seals intact
- Wiring
- CT inputs: Connect phase CTs to Ia, Ib, Ic; residual CT to Io (observe polarity!)
- Auxiliary power: L/N to terminals 11/12 (88–265 V AC/DC)
- Binary I/O: Assign per single-line diagram (e.g., trip coil to BO1)
- Communication: Ethernet to substation LAN; RS-485 for legacy Modbus
- Commissioning (via PCM600)
- Connect laptop to Ethernet port; launch PCM600
- Upload project configuration (CID file for IEC 61850)
- Perform Primary Injection Test: Verify pickup/delay settings with test set
- Enable protection functions; document settings in protection log
⚠️ Common Pitfalls:
- Reversed CT polarity → false ground fault trips
- Incorrect CT ratio in software → misoperation during faults
- Skipping primary injection test → undetected wiring errors
❓ Frequently Asked Questions
Q1: Why does my documentation say “PM902F” but the device label shows REF615?
A: “PM902F” is not an ABB product. Possible causes:
- Legacy internal naming from EPC contractor
- Confusion with Siemens 7SJ62 (sometimes informally called “PM” series)
- Typographical error in purchase order
Always trust the physical label and ABB ordering code (3BDH…).
Q2: Can I configure this relay without PCM600?
A: Limited local configuration via front keypad (LED menu) is possible for basic settings. However, full protection logic, IEC 61850 mapping, and firmware updates require PCM600. ABB does not provide free standalone configuration tools.Q3: How to verify firmware version?
A: In PCM600: Device → Properties → Firmware. Typical shipped version: V3.2x. Critical: Firmware must match project CID file version. Mismatch causes IEC 61850 communication failure.Q4: Is this relay suitable for arc-flash mitigation?
A: No. REF615 lacks dedicated arc-sensor inputs and ultra-fast trip logic (<4 ms). For arc-flash applications, select REF620 (with arc protection option) or dedicated arc-flash relay (e.g., ABB Arc Guard System™).Q5: What’s the difference between 3BDH001000R0001 and 3BDH000100R0001?
A: Suffix variations denote hardware options:
3BDH000100R0001: Base model (example)3BDH001000R0001: Specific configuration (e.g., universal power supply, standard I/O)
Always cross-reference with ABB’s Ordering Guide for Relion 615 (document 1MRS757697).
Q6: Can I replace an old electromechanical relay (e.g., GEC ALSTOM) with this?
A: Yes—this is a primary use case. However:
- Verify CT compatibility (burden, accuracy class)
- Update single-line diagrams and protection coordination study
- Retrain operations staff on digital interface
Budget 4–8 hours for commissioning vs. legacy relay swap.
Q7: What warranty/test validation do you provide for surplus units?
A: For genuine surplus:
- Serial number verified against ABB database
- Functional test: Protection logic validation, communication handshake, LED/display check
- Test report includes firmware version, thermal image, and primary injection results
- 12-month warranty against manufacturing defects
Always request test documentation before purchase.
- WhatsApp: +86 18030182217
- Email: sandydcsplc@gmail.com
- Phone: +86 18030182217
- Wechat: +86 18030182217
- Website: www.xiongbaparts.com


+86 18030182217
+86 18030182217
sandydcsplc@gmail.com