ABB ARCOL 0346 Thermal-Magnetic Circuit Breaker(XIONGBA)

Brand Model Summary

  • Brand ModelABB ARCOL 0346
  • Product Name: 3-Pole Thermal-Magnetic Circuit Breaker
  • Warranty: 1 year
  • Size: 90 mm (W) × 100 mm (H) × 80 mm (D)
  • Weight: 0.7 kg
  • Origin: China
  • Inventory: Spot
  • Delivery Time: 3 days after payment
Category: Brand:
  • Need Help?
  • +86 18030182217
  • +86 18030182217
  • sandydcsplc@gmail.com
库存图标
100,000+ Models in Stock
保修图标
One-Year Warranty
响应图标
24h Fast Response

Description

Product Overview

The ABB ARCOL 0346 is a 3-pole, 46A, 690V AC thermal-magnetic circuit breaker engineered for industrial and commercial applications requiring robust overcurrent protection. Designed with ABB’s signature reliability, this breaker combines thermal overload and magnetic short-circuit protection to safeguard critical systems against damage from excessive currents, short circuits, and ground faults. Unlike motor control modules (e.g., ARCOL 0338/0339), the ARCOL 0346 focuses on circuit protection, making it ideal for power distribution panels, motor control centers (MCCs), and heavy machinery where precise fault interruption is essential.

 

Key components include a bimetallic strip for gradual overcurrent detection and a solenoid-driven magnetic trip mechanism for instantaneous short-circuit response. The module’s IP20-rated enclosure resists dust and solid particles, ensuring durability in harsh environments like manufacturing plants or outdoor substations. With a compact design optimized for DIN rail mounting, the ARCOL 0346 integrates seamlessly into existing switchgear or new installations, supporting auxiliary contacts and shunt trip coils for remote monitoring and control.

 

In automation systems, the ARCOL 0346 acts as a foundational layer of safety, preventing equipment failure and downtime. Its adjustable thermal trip settings (0.7–1.0x motor rated current) and fixed magnetic trip threshold balance flexibility with precision, while CE and UL 60947-2 certifications ensure compliance with global safety standards. By reducing maintenance costs through modular replaceable parts and hot-swap capabilities, the ARCOL 0346 delivers long-term value for industries ranging from water treatment to oil & gas.

Technical Specifications

Parameter Name Parameter Value
Product Model ABB ARCOL 0346
Manufacturer ABB
Product Type Thermal-Magnetic Circuit Breaker
Rated Current 46 A
Rated Voltage 690 V AC
Number of Poles 3
Tripping Characteristics Thermal (adjustable) + Magnetic (fixed)
Short-Circuit Breaking Capacity (Icu) 100 kA at 400 V AC
Enclosure Rating IP20
Operating Temperature -5°C to +40°C
Certifications CE, UL 60947-2
Mounting 35 mm DIN rail
Wiring Terminals 4–16 mm² stranded wires

Key Features and Advantages

Dual-Element Protection:
The ARCOL 0346 employs thermal-magnetic tripping technology to address both gradual overcurrents and sudden short circuits. The bimetallic strip responds to prolonged overloads by bending and triggering a mechanical trip, while the solenoid-based magnetic element interrupts high-energy faults within milliseconds. This dual-layer protection minimizes downtime and extends equipment lifespan in applications like pumps, compressors, and conveyor systems.

 

High Fault-Clearing Capacity:
With an Icu rating of 100 kA at 400 V AC, the ARCOL 0346 effectively handles extreme fault conditions common in heavy industries. Its robust design ensures reliable performance in mining, steel production, and power generation, where high short-circuit currents pose significant risks.

 

Compact and Rugged Design:
The IP20-rated enclosure protects against dust and debris, while the lightweight construction (dimensions: 90 mm width × 100 mm height × 80 mm depth) allows easy integration into space-constrained control panels. Operating across a wide temperature range (-5°C to +40°C), the breaker maintains stability in environments with fluctuating conditions.

 

Flexible Control Options:
Modular accessories like auxiliary contacts and shunt trip coils enable remote status monitoring and emergency tripping, enhancing compatibility with PLCs and SCADA systems. This flexibility is critical for centralized control in water treatment plants or commercial HVAC systems, where real-time fault management is essential.

 

Cost-Effective Maintenance:
The ARCOL 0346 features a replaceable trip unit and hot-swap capability, reducing downtime during repairs. Routine maintenance is simplified through visual status indicators and easy access to terminals, while the DIN rail mount design streamlines installation and replacement.

Application Areas

Power Distribution:
The ARCOL 0346 protects main feeders and branch circuits in industrial switchgear, ensuring safe load management and fault isolation. Its high Icu rating makes it suitable for utility substations and renewable energy farms, where grid stability is paramount.

 

Motor Control Centers (MCCs):
Integrated with contactors, the ARCOL 0346 provides combined motor protection and switching for high-power applications. It safeguards pumps, compressors, and fans in wastewater treatment plants, preventing damage from dry running or unbalanced phases.

 

Heavy Industry:
Deployed in mining equipment, steel mills, and chemical plants, the breaker withstands corrosive environments and high vibrations. Its thermal-magnetic design ensures reliable operation in systems exposed to frequent load variations.

 

Commercial Buildings:
Used in HVAC systems, elevators, and lighting circuits, the ARCOL 0346 ensures compliance with safety standards while optimizing energy efficiency. Its adjustable trip settings adapt to varying loads in office complexes or retail facilities.

 

Renewable Energy:
In solar and wind farms, the breaker protects inverters, transformers, and battery storage systems from overcurrent and short-circuit faults, supporting grid integration and system reliability.

Related Products

  1. ABB ARCOL 0338: A motor control module for soft-start applications, complementing the ARCOL 0346 in MCCs requiring both protection and precise motor regulation.
  2. ABB ARCOL 0339: A solid-state motor controller with advanced diagnostics, ideal for applications demanding smooth startup and torque control alongside the ARCOL 0346’s circuit protection.
  3. ABB SACE Tmax XT: A higher-current circuit breaker (up to 1600 A) for main distribution panels, serving as an upgrade for large-scale industrial systems.
  4. ABB AF Series Contactors: Complementary devices for motor switching, designed to work seamlessly with the ARCOL 0346 in MCC configurations.
  5. ABB EMplus Relays: Electronic protection relays offering advanced monitoring features, enhancing the ARCOL 0346’s diagnostic capabilities in critical systems.

Installation and Maintenance

Installation Preparation:
Before installing the ARCOL 0346, verify the ABB ARCOL 0346’s compatibility with your system voltage (690 V AC) and motor rating (up to 46 A). Mount the breaker on a 35 mm DIN rail in a well-ventilated control cabinet, ensuring at least 20 mm clearance for heat dissipation. Use 4–16 mm² stranded wires with a torque of 0.8–1.2 N·m for power connections, and secure control wiring (e.g., auxiliary contacts) to prevent 松动.

 

Maintenance Recommendations:
Regularly inspect the ARCOL 0346 for signs of overheating or physical damage. Test the thermal and magnetic trip mechanisms annually using ABB’s diagnostic tools to ensure accuracy. Clean dust from vents monthly to maintain thermal efficiency, and lubricate moving parts (e.g., trip levers) with non-conductive grease every six months. Replace the breaker immediately if the enclosure shows cracks or if the trip unit fails calibration.

Product Assurance

ABB guarantees the ARCOL 0346 against defects in materials and workmanship for 1 year from the date of purchase. The company provides global technical support, including 24/7 troubleshooting assistance and system integration guidance. ABB’s network of certified service centers ensures prompt repairs and replacements, while online resources (e.g., firmware updates, installation manuals) support ongoing optimization. With a commitment to sustainability and safety, ABB’s products undergo rigorous testing to meet international standards, ensuring the ARCOL 0346 delivers reliable performance in even the most demanding environments.

 

For detailed technical documentation or to inquire about inventory, contact your local ABB representative or visit the ABB eFinder portal.

 

Note: While the ARCOL 0346 shares the “ARCOL” branding with motor control modules, it is a distinct product focused on circuit protection. Always verify compatibility with your system requirements before deployment.
HS:8536200000