Product Overview
The ABB RED670 1MRK002810‑AC is a high‑performance line differential protection IED belonging to the ABB Relion 670 platform. It is designed for high‑speed selective protection of overhead transmission lines, cable feeders and multi‑terminal lines up to 5 terminals, also applicable for lines with integrated power transformers. It integrates differential protection, distance protection, backup overcurrent protection, breaker control, disturbance recording and comprehensive substation communication interfaces. It is widely used as spare‑part for maintenance, retrofitting and refurbishment of existing power plant and utility substation protection panelsManualsLib.
Series
Relion 670 Series. This modular IED family covers line protection, bay control, transformer protection and generator protection devices for transmission and distribution substations. The series supports IEC 61850 digital substation standard, flexible application configuration and unified PCM600 engineering tool for power system protection applications.
Product Features
- Advanced phase‑segregated line differential protection for 2‑5 terminal lines, high fault resistance coverage capabilityABB У…
- Multi‑zone distance protection with quadrilateral and mho characteristics, power swing detection, pole‑discrepancy protection, stub protection and breaker‑failure protectionManualsLib
- Complete set of backup protection: phase/earth overcurrent, negative‑sequence overcurrent, sensitive residual overcurrent protection
- Built‑in disturbance recorder, fault locator, timestamped event log for post‑fault analysis
- Rich communication portfolio: IEC 61850‑8‑1, IEC 60870‑5‑103, DNP3.0, SPA, LON protocols; supports fiber tele‑protection interfaceManualsLib
- Local HMI display for parameter checking, status indication and manual operation
- Flexible configurable logic for site‑specific bay‑control requirements
- Support one‑phase, two‑phase or three‑phase tripping schemes
- Engineering configuration via ABB PCM600 software toolset
- Panel‑mount or 19‑inch rack‑mount mechanical form factor for protection cabinet installation
Product Parameters
| Item | Value |
|---|---|
| Part Number | RED670 1MRK002810‑AC |
| Device Type | Line Differential Protection IED |
| Rated CT Input | 1 A / 5 A selectable |
| Auxiliary Supply | 48‑250 VDC / 100‑240 VAC |
| Protection Trip Time | High‑speed differential operation <20 ms typical |
| Communication | Ethernet, optical tele‑protection, serial ports |
| Mounting | Panel mount / 19‑inch rack mount |
| Operating Temperature | ‑25 °C ~ +55 °C |
| Insulation Test | 2 kV AC for 1 minute per ANSI C37.90 |
| Software Tool | PCM600 |
| Certifications | IEC, ANSI, CE compliant |
| Weight | 5.5‑9.0 kg |
| Origin | Sweden |
Product Specifications
- Fault recording: Multi‑channel oscillography capture for current, voltage and binary signals
- Fault locator: Calculates fault distance for overhead‑line troubleshooting
- Binary I/O: Configurable digital inputs and relay outputs for breaker interlock and alarm
- Time synchronization: IRIG‑B, SNTP, IEC 61850 time sync support
- Compatibility: Designed for transmission and sub‑transmission line protection cabinets
- Lifecycle: Original manufacturing discontinued; available as surplus / refurbished spare‑part units
- Application note: Suitable for overhead lines, underground cables and multi‑terminal network topologies
Function
- High‑speed line differential main protection for overhead and cable transmission circuits
- Distance protection and multi‑stage overcurrent protection as main and backup protection
- Breaker control, interlock logic and bay‑level status monitoring
- Fault location, disturbance waveform capture and time‑stamped event logging for fault diagnosis
- Local HMI human‑machine interaction for inspection and manual operation
- Bidirectional data exchange with SCADA / substation automation system via multiple communication protocols
- Flexible logic programming to adapt complex substation bay‑control requirements
Purpose
Provide main and backup protection for transmission lines and multi‑terminal power circuits; record fault data for power‑system post‑incident analysis; act as critical spare‑part for existing substation protection panel maintenance and retrofit projects.
Application Fields
- Utility power transmission and sub‑transmission substations
- Captive power plant transmission outgoing‑feeders protection
- Oil & gas large‑scale on‑site power‑grid protection cabinets
- Heavy‑industry large‑factory internal power‑system protection retrofit
- Renewable‑energy plant transmission‑line protection panel renewal
- Substation upgrade and legacy protection‑device replacement projects