Model: FC‑TSPKUNI‑1624Brand: HoneywellSeries: Safety Manager Safety Instrumented SystemCore Function: RUSIO field signal termination, channel‑by‑channel fuse protection, field‑wiring interface for safety I/OProduct Type: Field Termination Assembly (FTA) Knife Terminal ModuleKey Specifications: 16‑channel RUSIO interface, 24 VDC field power, 2 A per‑channel blade fuses, 37‑pin Sub‑D connector, DIN‑rail mount, TUV SIL3 certified, successor part FC‑TSPKUNI‑1624RHoneywellObsolete Status: Obsolete / End‑of‑life
Product Overview
The Honeywell FC‑TSPKUNI‑1624 is a dedicated field termination assembly for Honeywell Safety Manager SIS RUSIO remote I/O system. It converts 37‑pin Sub‑D controller interface into field‑wirable knife‑style terminals for 16 safety I/O channels, with individual channel fuse protection for 24 VDC field circuits. This FTA acts as physical wiring bridge between Safety Manager RUSIO modules and field sensors / actuators. Original manufacturing is discontinued; replacement part number is FC‑TSPKUNI‑1624R, widely used as spare‑part for existing safety instrumented system maintenance and retrofit projectsHoneywell.
Series
Safety Manager SIS Series. Honeywell Safety Manager platform delivers SIL3‑grade safety control for ESD, F&G and process shutdown systems, including RUSIO remote I/O modules, controllers, power supplies and complete range of FTA field termination assemblies for field signal connection.
Product Features
- 16 independent RUSIO signal channels, each equipped with 2 A blade fuse for over‑current protection
- 37‑pin male Sub‑D connector for direct connection to Safety Manager RUSIO I/O modules
- Knife‑type terminal blocks: each channel provides fused +24 VDC power, signal and common 0V connection
- External 24 VDC field power input connector for supplying field instruments
- Standard DIN‑rail TS35 mounting for control cabinet installation
- TUV certified for SIL3 safety system integration, CE, UL, CSA compliant
- Replaceable 5×19 mm blade fuses per channel for easy on‑site troubleshooting and repair
- Total maximum field load capacity up to 16 A
- Drop‑in replacement compatible; superseded by FC‑TSPKUNI‑1624R revision variantHoneywell
Product Parameters
| Item | Value |
|---|---|
| Part Number | FC‑TSPKUNI‑1624 |
| Module Type | RUSIO Field Termination Assembly (FTA) |
| Channel Count | 16 RUSIO I/O channels |
| Field Supply Voltage | 24 VDC nominal, max 32 VDC DC rating |
| Per‑Channel Fuse Rating | 2 A blade fuse (5×19 mm) |
| Max Total Field Load | 16 A |
| System Connector | 37‑pin Male Sub‑D |
| Field Terminals | Knife‑style 3‑pole per channel |
| Mounting | DIN‑rail TS35 standard rail |
| Safety Certification | TUV IEC 61508 SIL3, CE, UL, CSA |
| Operating Temperature | -20 °C ~ +70 °C |
| Humidity | 5‑95 % non‑condensing |
| Dimension | 175 mm × 70 mm × 57 mm |
| Weight | 0.64 kg |
| Successor Part | FC‑TSPKUNI‑1624RHoneywell |
Product Specifications
- Electrical isolation: Galvanic separation between field wiring and controller back‑plane
- Fuse function: Individual channel over‑current protection prevents single‑channel fault spreading to other safety loops
- Mechanical: Snap‑in DIN‑rail installation, compact cabinet‑friendly form‑factor
- Compatibility: Matches Honeywell Safety Manager RUSIO remote I/O hardware
- Lifecycle: Original production withdrawn March‑2022, available as surplus / refurbished spare parts onlyHoneywell
- Wiring: Designed for field sensors, solenoid valves and safety‑related 24VDC field devices
Function
- Provide physical termination interface between Safety Manager RUSIO I/O modules and field safety instruments
- Distribute 24 VDC field power to each I/O channel with individual fuse protection
- Isolate field wiring faults to single channel, avoid fault propagation across safety loops
- Offer convenient knife‑terminal access for field‑loop testing, commissioning and maintenance work
- Maintain system‑level SIL3 safety integrity when deployed within certified Safety Manager architecture
Purpose
Serve as field‑wiring interface unit for Honeywell Safety Manager SIS; protect safety I/O circuits from field short‑circuit and overload; provide accessible test points for safety‑loop commissioning and troubleshooting; critical spare‑part for legacy SIS system repair and cabinet retrofit.
Application Fields
- Oil & gas on‑shore and offshore ESD emergency shutdown systems
- Petrochemical and refinery safety instrumented system cabinet maintenance
- Chemical plant fire & gas detection safety control retrofit projects
- Power plant safety protection system spare‑part replacement
- Pulp & paper mill Safety Manager SIS hardware renewal